kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Woven Electroanalytical Biosensor for Nucleic AcidAmplification Tests
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Fibre- and Polymer Technology, Fibre Technology. (Hamedi lab)ORCID iD: 0000-0001-7002-1382
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Fibre- and Polymer Technology, Fibre Technology.ORCID iD: 0000-0002-0127-9782
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Fibre- and Polymer Technology, Fibre Technology.ORCID iD: 0000-0002-1208-8009
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Fibre- and Polymer Technology, Fibre Technology.ORCID iD: 0000-0003-0788-5107
Show others and affiliations
2021 (English)In: Advanced Healthcare Materials, ISSN 2192-2640, E-ISSN 2192-2659, Vol. 10, no 11, p. 2100034-Article in journal (Refereed) [Artistic work] Published
Abstract [en]

Fiber-based biosensors enable a new approach in analytical diagnosticdevices. The majority of textile-based biosensors, however, rely oncolorimetric detection. Here a woven biosensor that integrates microfluidicsstructures in combination with an electroanalytical readout based on athiol-self-assembled monolayer (SAM) for Nucleic Acid Amplification Testing,NAATs is shown. Two types of fiber-based electrodes are systematicallycharacterized: pure gold microwires (bond wire) and off-the-shelf plasmagold-coated polyester multifilament threads to evaluate their potential to formSAMs on their surface and their electrochemical performance in woven textile.A woven electrochemical DNA (E-DNA) sensor using a SAM-based stem-loopprobe-modified gold microwire is fabricated. These sensors can specificallydetect unpurified, isothermally amplified genomic DNA of Staphylococcusepidermidis (10 copies/μL) by recombinase polymerase amplification (RPA).This work demonstrates that textile-based biosensors have the potential forintegrating and being employed as automated, sample-to-answer analyticaldevices for point-of-care (POC) diagnostics.

Place, publisher, year, edition, pages
Wiley-VCH Verlagsgesellschaft, 2021. Vol. 10, no 11, p. 2100034-
Keywords [en]
Woven electroanalytical microfluidic devices, DNA biosensors, Fiber electrodes, Self assembled monolayers (SAM)
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-301909DOI: 10.1002/adhm.202100034ISI: 000645682300001PubMedID: 33930257Scopus ID: 2-s2.0-85105138834OAI: oai:DiVA.org:kth-301909DiVA, id: diva2:1594140
Funder
EU, European Research Council
Note

QC 20210917

Available from: 2021-09-14 Created: 2021-09-14 Last updated: 2022-12-07Bibliographically approved
In thesis
1. Textile and Paper Microfluidic Platforms for Electroanalytical Nucleic Acid Testing
Open this publication in new window or tab >>Textile and Paper Microfluidic Platforms for Electroanalytical Nucleic Acid Testing
2021 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Rapid and accurate near-patient diagnostic tests outside well-equipped laboratories are essential in the fight against outbreaks of infectious diseases, especially when these can turn into pandemics. As severe acute respiratory syndrome CoV 2 (SARS-CoV-2) is the latest but probably not the last pandemic of the 21st century. Nucleic acid amplification tests (NAATs) identify pathogens at the molecular level by targeting specific gene sequences. NAATs are currently the gold standard of molecular diagnostics, given their reliability, sensitivity, and specificity. In addition, NAATs can provide quantitative results with a short turnaround time compared to conventional immunoassays or culturing methods. However, most NAATs necessitate centralized laboratories and trained health professionals and, to a large extend, fail to be point-of-care(POC).The biosensing field was inspired by the micro electronics revolution in the1980s, which led to the emergence of the micro-total analysis systems (μTAS)concept. μTAS was envisioned to miniaturized laboratory-based tests in single microfluidic devices. The combination of POC NAATs with μTAS can offer rapid, sensitive, and specific diagnostic tools of great importance in tackling diseases.In this thesis, we have utilized paper and textile materials as a platform for developing μTAS. These materials possess many features necessary for advanced μTAS, such as the ability to transport liquids, store reagents and embed electronic functions, making them ideal for integrating affordable, portable, and easy to manufacture μTAS for NAATs.We have specially developed NAATs with paper-based and thread-based electrochemical readout to provide quantitative responses with high sensitivity, specificity, and the possibility to connect to portable digital electronics. This work paves the way for robust sample-to-answer digital POC NAATs.

Abstract [sv]

Snabba och noggranna diagnostiska tester som utförs nära patienten utanför välutrustade laboratorier är det mest avgörande sättet att ta itu med smittsamma sjukdomar, som i värsta fall kan förvandlas till en pandemi.Severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) är den senaste men förmodligen inte den sista pandemin under 2000-talet.Nukleinsyraamplifieringstest (NAAT) identifierar patogener på en molekylär nivå genom att rikta in på specifika gensekvenser. NAAT är för tillfället den gyllene standarden för molekylär diagnostisk teknik med tanke på desstillförlitlighet, känslighet, och specificitet Utöver detta ger NAAT kvantitativa resultat med en kort behandlingstid i motsats till konventionella immunanalyser eller odlingsmetoder. De flesta NAAT-metoder kräver dock centraliserade laboratorier och utbildad personal och är därmed inte anpassade för självtest nära patienten.Biosensorsfältet var inspirerat av mikroelektronikrevolutionen på 1980-talet, vilket ledde till uppkomsten av konceptet mikrototalanalyssystem(μTAS). Dessa system har som syfte att miniatyrisera laboratoriebaserade tester genom att utföra alla steg i enstaka mikrofluidanordningar.Kombineringen av patientnära NAAT-tester med μTAS kan därför erbjuda snabba, känsliga och specifika diagnostikverktyg och därmed ha stor påverkan för att förhindra överföring av infektionssjukdomar. I den här avhandlingen har vi använt papper och textila material som en platform utveckling av μTAS.Dessa material har många egenskaper som är nödvändiga för μTAS såsom förmågan att transportera vätskor, lagra reagenser och att integrera elektroniska funktioner, vilket gör dem ideala för att integrera prisvärda, bärbara och lättillverkade μTAS för NAAT-tester. Vi har speciellt utvecklat NAAT-tekniker med papper- och trådbaserad elektrokemisk avläsning som ger kvantitativa svar med hög känslighet,specificitet och möjlighet att ansluta till bärbara elektroniska enheter. Detta arbete banar vägen för robusta, digitala och patientnära prov-till-svar-tester som baseras på NAAT-teknik.

Place, publisher, year, edition, pages
Stockholm, Sweden: KTH Royal Institute of Technology, 2021. p. 61
Series
TRITA-CBH-FOU ; 2021:33
National Category
Medical Biotechnology (with a focus on Cell Biology (including Stem Cell Biology), Molecular Biology, Microbiology, Biochemistry or Biopharmacy)
Research subject
Fibre and Polymer Science
Identifiers
urn:nbn:se:kth:diva-302471 (URN)
Public defence
2021-10-18, Kollegiesalen, Brinellvägen 8, KTH, Stockholm, 14:00 (English)
Opponent
Supervisors
Funder
EU, European Research Council, 715268
Note

QC 2021-09-24

Available from: 2021-09-24 Created: 2021-09-24 Last updated: 2022-10-31Bibliographically approved

Open Access in DiVA

fulltext(4000 kB)397 downloads
File information
File name FULLTEXT01.pdfFile size 4000 kBChecksum SHA-512
87fd529cf87c46f0de2e8e179f661a14cbbae658cef677513356803d81c7e3baec1dc3a8e0ae7a212e6b87be1f6c1fc50a61713ffd8d0529dda477f072e098d6
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopushttps://onlinelibrary.wiley.com/doi/full/10.1002/adhm.202100034

Authority records

Khaliliazar, ShirinÖberg Månsson, IngridPiper, AndrewOuyang, LiangqiReu, PedroHamedi, Mahiar

Search in DiVA

By author/editor
Khaliliazar, ShirinÖberg Månsson, IngridPiper, AndrewOuyang, LiangqiReu, PedroHamedi, Mahiar
By organisation
Fibre TechnologyNano BiotechnologyAffinity ProteomicsScience for Life Laboratory, SciLifeLab
In the same journal
Advanced Healthcare Materials
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 397 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 231 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf