A Non-Intrusive and Non-Destructive Technique for Condition Assessment of Transformer Liquid Insulation
Indian Inst Technol Guwahati, Sch Energy Sci & Engn, Gauhati 781039, India..
Indian Inst Technol Guwahati, Sch Energy Sci & Engn, Gauhati 781039, India.;Indian Inst Technol Guwahati, Dept Elect & Elect Engn, Gauhati 781039, India..
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electromagnetic Engineering.ORCID iD: 0000-0002-6375-6142
2022 (English)In: IEEE transactions on dielectrics and electrical insulation, ISSN 1070-9878, E-ISSN 1558-4135, Vol. 29, no 2, p. 1-1Article in journal (Refereed) Published
Abstract [en]

The insulation system in a transformer degrades over time and it needs periodic monitoring for uninterrupted operation of the power system network. Moisture content (MC), acid number, and dissolved gases are the important parameters that establish the aging and degradation status of the transformer liquid insulation. This work focuses on using high-frequency signals nonintrusively for estimating the degradation of the transformer liquid insulation by considering the MC and acid content. A novel nonintrusive and nondestructive testing method using an S-band pyramidal horn antenna is introduced in this work to estimate the degradation of the liquid insulation with respect to aging duration. The scattering parameter S-11 of the liquid insulation is first characterized and measured in an anechoic chamber to avoid electromagnetic interference (EMI). These tests are performed initially on laboratory-aged mineral oil (MO) samples and a prediction curve of vertical bar S-11 vertical bar as a function of moisture and acid number is obtained. vertical bar S-11 vertical bar of the in-service transformer oil samples is then compared with the prediction curve and the degradation status is predicted. It is found that the chosen frequency band is able to differentiate the aging status of MO accurately. This technique can be used for establishing the degradation status of any type of liquid insulation. A miniature version of the proposed technique can be used for portable and faster condition assessment of insulating oils.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE) , 2022. Vol. 29, no 2, p. 1-1
Keywords [en]
Condition assessment, high-frequency signals, liquid insulation, noninvasive, nondestructive
National Category
Polymer Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-312796DOI: 10.1109/TDEI.2022.3157912ISI: 000790818900046Scopus ID: 2-s2.0-85126326545OAI: oai:DiVA.org:kth-312796DiVA, id: diva2:1661078
Note

QC 20220525

Available from: 2022-05-25 Created: 2022-05-25 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Becerra Garcia, Marley

Search in DiVA

By author/editor
Becerra Garcia, Marley
By organisation
Electromagnetic Engineering
In the same journal
IEEE transactions on dielectrics and electrical insulation
Polymer Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 122 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf