A Bioimpedance Spectroscopy Interface for EIM Based on IF-Sampling and Pseudo 2-Path SC Bandpass ΔΣ ADC
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electronics and Embedded systems. (Mixed-Signals ICs and Systems)ORCID iD: 0000-0001-7549-0858
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electronics and Embedded systems. (Mixed Signal ICs & Systems)ORCID iD: 0000-0003-1736-8701
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electronics and Embedded systems. (Mixed Signal ICs & Systems)ORCID iD: 0000-0003-0565-9907
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electronics and Embedded systems. (Mixed Signal ICs & Systems)ORCID iD: 0000-0003-3802-7834
2024 (English)In: IEEE Transactions on Biomedical Circuits and Systems, ISSN 1932-4545, E-ISSN 1940-9990, Vol. 18, no 5, p. 1001-1013Article in journal (Refereed) Published
Abstract [en]

This paper presents a low-noise bioimpedance (bio-Z) spectroscopy interface for electrical impedance myography (EIM) over the 1 kHz to 2 MHz frequency range. The proposed interface employs a sinusoidal signal generator based on direct-digital-synthesis (DDS) to improve the accuracy of the bio-Z reading, and a quadrature low-intermediate frequency (IF) readout to achieve a good noise-to-power efficiency and the required data throughput to detect muscle contractions. The readout is able to measure baseline and time-varying bio-Z by employing robust and power-efficient low-gain IAs and sixth-order single-bit bandpass (BP) ΔΣ ADCs. The proposed bio-Z spectroscopy interface is implemented in a 180 nm CMOS process, consumes 344.3 - 479.3 μ W, and occupies 5.4 mm 2 area. Measurement results show 0.7 mΩ/√Hz sensitivity at 15.625 kHz, 105.8 dB SNR within 4 Hz bandwidth, and a 146.5 dB figure-of-merit. Additionally, recording of EIM in time and frequency domain during contractions of the bicep brachii muscle demonstrates the potential of the proposed bio-Z interface for wearable EIM systems.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2024. Vol. 18, no 5, p. 1001-1013
Keywords [en]
Bioimpedance spectroscopy, electrical impedance myography, analog front-end, sinusoidal signal generator, instrumentation amplifier, bandpass sigma-delta modulator, low-noise.
National Category
Medical Engineering Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering; Medical Technology
Identifiers
URN: urn:nbn:se:kth:diva-345246DOI: 10.1109/tbcas.2024.3370399ISI: 001322633800013PubMedID: 38408001Scopus ID: 2-s2.0-85186995458OAI: oai:DiVA.org:kth-345246DiVA, id: diva2:1850586
Funder
Swedish Foundation for Strategic Research, ITM17-0079
Note

QC 20241029

Available from: 2024-04-10 Created: 2024-04-10 Last updated: 2024-10-29Bibliographically approved
In thesis
1. Fully Integrated Bioimpedance Spectroscopy Interface for Wearable Electrical Impedance Myography
Open this publication in new window or tab >>Fully Integrated Bioimpedance Spectroscopy Interface for Wearable Electrical Impedance Myography
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Multi-Frequency surface Electrical Impedance Myography (MF-sEIM) is a technique that provides valuable electrophysiological information of muscles. This technique measures bio-Z spectroscopy of muscles, and applies Ohm's law by injecting a small-amplitude and high-frequency current into tissues and measuring the voltage response. As biological tissues are electrolytic conductors, this technique provides information on fundamental dielectric properties of tissues, which are an objective biomarker of neuromuscular disorders and have practical value in several muscle healthcare applications. Due to its versatility, simplicity, and ease of integration, this technique is a great candidate to complement stand-alone surface electromyography (sEMG) in wearable devices for continuous monitoring of muscle health. Nonetheless, wearable MF-sEIM imposes challenging requirements on the bio-Z spectroscopy interface. Previously reported solutions fall short of meeting these requirements, or do so with low power efficiency.

This thesis focuses on the research and development of a fully integrated bio-Z spectroscopy interface, which complies with the challenging requirements of wearable MF-sEIM in a power-efficient way. The electrophysiological mechanisms of MF-sEIM and the system-level requirements for clinical relevance were investigated, as MF-sEIM is a relatively novel technique, which requires standarization. From this established set of requirements, the main building blocks of the \mbox{bio-Z} spectroscopy interface, i.e., the current signal generator (CSG), and voltage readout, were developed. The CSG generates pseudo-sine waves through direct digital synthesis (DDS) to obtain the required linearity with high power efficiency. A high-linearity full current-mode CSG was also proposed to comply with the stricter bio-Z accuracy requirements of clinical diagnostics. The voltage readout is based on a low-IF quadrature (I/Q) demodulation architecture and features a pseudo 2-path bandpass (BP) Delta-Sigma ADC to achieve high precision and power-to-noise efficiency. A mixer-first analog front-end (AFE) was also proposed to enable bio-Z spectroscopy measurements employing dry electrodes. The bio-Z interface was integrated with a 16-Channel sEMG AFE and a 4-Channel neuromuscular stimulator (NMES) in an application-specific integrated circuit (ASIC). Experimental results show that the implemented bio-Z spectroscopy interface achieves a comparable performance with the state of the art, while being capable of detecting the large baseline and the time-varying impedances of muscle. A proof-of-concept system, based on the multi-modal ASIC, was developed. This system demonstrates the potential of combining real-time monitoring of MF-sEIM and sEMG for detecting muscle fatigue, enabling efficient closed-loop NMES.

Abstract [sv]

Multifrekvent ytelektroimpedansmyografi (MF-sEIM) är en teknik som ger värdefull elektrofysiologisk information om muskler. Denna teknik mäter bioimpedans-spektroskopi (bio-Z-spektroskpi) av muskler och tillämpar Ohms lag genom att injicera en högfrekvent småsignalström i vävnader och mäta spänningssvaret. Eftersom biologiska vävnader är elektrolytiska ledare, ger denna teknik information om grundläggande dielektriska egenskaper hos vävnader, som är en objektiv biomarkör för neuromuskulära störningar och har praktiskt värde i flera tillämpningar för muskelsjukvård. På grund av dess mångsidighet och enkel integration är denna teknik en utmärkt kandidat för att komplettera fristående ytelektromyografi (sEMG) i bärbara enheter för kontinuerlig övervakning av muskelhälsa. Icke desto mindre ställer bärbar MF-sEIM utmanande krav på bio-Z-spektroskopigränssnittet. Tidigare rapporterade lösningar uppfyller inte dessa krav, eller gör det med låg energieffektivitet.

Denna avhandling fokuserar på forskning och utveckling av ett helt integrerat bio-Z-spektroskopigränssnitt, som uppfyller de utmanande kraven för bärbar MF-sEIM på ett energieffektivt sätt. De elektrofysiologiska mekanismerna för MF-sEIM och kraven på systemnivå för klinisk relevans undersöktes, eftersom MF-sEIM är en relativt ny teknik som kräver standardisering. Från de definerade kraven på systemnivå utvecklades huvudbyggstenarna för bio-Z-spektroskopigränssnittet, dvs. strömsignalgeneratorn (CSG) och spänningsavläsningen. CSG genererar pseudo-sinusvågor genom direkt digital syntes (DDS) för att erhålla den erforderliga linjäriteten med hög energieffektivitet. En CSG i fullströmsläge med hög linjäritet föreslogs också för att uppfylla de striktare noggrannhetskraven på bioimpedansmätning för klinisk diagnostik. Spänningsavläsningen är baserad på en demoduleringsarkitektur med låg IF-kvadratur (I/Q) och har en pseudo 2-vägs bandpass (BP) Delta-Sigma ADC för att uppnå hög precision och energi till brus effektivitet. En mixer-framför analog front-end (AFE) föreslogs också för att möjliggöra bio-Z-spektroskopimätningar med användning av torra elektroder. Bio-Z-gränssnittet integrerades med en 16-kanals sEMG AFE och en 4-kanals neuromuskulär stimulator (NMES) i en applikationsspecifik integrerad krets (ASIC). Experimentella resultat visar att det implementerade bio-Z-spektroskopigränssnittet uppnår en prestanda som är jämförbar med den senaste tekniken, samtidigt som den kan detektera storsignalsimpedansen hos muskler och dess tidsvariation. Ett prototyp, baserat på den multimodala ASIC, utvecklades. Detta system visar potentialen i att kombinera realtidsövervakning av MF-sEIM och sEMG för att upptäcka muskeltrötthet, vilket möjliggör effektiva NMES med återkoppling.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2024. p. xix, 84
Series
TRITA-EECS-AVL ; 2024:62
Keywords
Musculoskeletal health, bioimpedance (bio-Z) spectroscopy, electrical impedance myography (EIM), biomedical modeling, ASIC, ultra-low power, high-precision, sinusoidal signal generator, readout, analog front-end, bandpass delta-sigma ADC, multi-modal sensing., Muskuloskeletal hälsa, bioimpedans-spectroscopi (bio-Z-spektroskpi), elektroimpedansmyografi (EIM), biomedicinsk modellering, ASIC, ultralåg energi, hög precision, sinusformad signalgenerator, avläsning, analog front-end, bandpass delta-sigma ADC, multimodal avkänning.
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Information and Communication Technology
Identifiers
urn:nbn:se:kth:diva-352340 (URN)978-91-8106-022-5 (ISBN)
Public defence
2024-09-27, https://kth-se.zoom.us/j/2593490856, Ka-Sal C, Electrum, Kistagången 16, Kista, 13:00 (English)
Opponent
Supervisors
Funder
Swedish Foundation for Strategic Research, ITM17-0079
Note

QC 20240829

Available from: 2024-08-29 Created: 2024-08-28 Last updated: 2026-01-13Bibliographically approved

Open Access in DiVA

fulltext(27934 kB)775 downloads
File information
File name FULLTEXT01.pdfFile size 27934 kBChecksum SHA-512
85fefe029fec6ba8fd53e7f3c921d33e9e736a791387d7d5aae4455bef69900899cb082b651d4a2b9e5940576b6bde4811f626ab78a331b4b81b915cb1eb3a5b
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Fernández Schrunder, AlejandroHuang, Yu-KaiRodriguez, SaulRusu, Ana

Search in DiVA

By author/editor
Fernández Schrunder, AlejandroHuang, Yu-KaiRodriguez, SaulRusu, Ana
By organisation
Electronics and Embedded systems
In the same journal
IEEE Transactions on Biomedical Circuits and Systems
Medical EngineeringOther Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 775 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 886 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf