Hot-wire spatial resolution issues in adverse pressure gradient turbulent boundary layers Show others and affiliations
2024 (English) In: Measurement, ISSN 0263-2241, E-ISSN 1873-412X, Vol. 237, article id 115229Article in journal (Refereed) Published
Abstract [en]
The effect of a finite length of hot-wire probe sensor length on the measured streamwise velocity fluctuations is well understood in canonical wall-bounded flow, where the small-scale energy has been found to be universal and invariant with Reynolds number. A straightforward application of that assumption to non-canonical flows such as strong adverse pressure gradient (APG) flows has, however, been hampered since the effect of Re and APG could not conclusively be studied separately due to the lack of data with a clear scale separation. The present experimental investigation at Reτ≈4000 in weak, moderate and strong APGs with different wire length shows that spatial averaging effects are not only limited to the inner layer. A note of caution is hence warranted for measurements that seemingly try to take the bias effect of spatial attenuation into account by performing measurements with albeit long but fixed viscous-scaled wire length.
Place, publisher, year, edition, pages Elsevier BV , 2024. Vol. 237, article id 115229
Keywords [en]
Adverse pressure gradient, Hot-wire anemometry, Turbulent boundary layer, Velocity fluctuations measurement
National Category
Fluid Mechanics
Identifiers URN: urn:nbn:se:kth:diva-350676 DOI: 10.1016/j.measurement.2024.115229 ISI: 001271887200001 Scopus ID: 2-s2.0-85198035032 OAI: oai:DiVA.org:kth-350676 DiVA, id: diva2:1884642
Note QC 20240719
2024-07-172024-07-172025-12-05 Bibliographically approved