kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Design control and actuator selection of a lower body assistive exoskeleton with 3-D passive compliant supports
KTH, School of Electrical Engineering and Computer Science (EECS), Intelligent systems, Robotics, Perception and Learning, RPL. Department of Electronics Mathematics and Science, University of Gävle, 80176, Gävle, Sweden.ORCID iD: 0000-0003-4712-7730
Department of Electronics Mathematics and Science, University of Gävle, 80176, Gävle, Sweden.
KTH, School of Electrical Engineering and Computer Science (EECS), Intelligent systems, Robotics, Perception and Learning, RPL.ORCID iD: 0000-0003-2078-8854
Department of Electronics Mathematics and Science, University of Gävle, 80176, Gävle, Sweden.
2023 (English)In: Journal of the Brazilian Society of Mechanical Sciences and Engineering, ISSN 1678-5878, E-ISSN 1806-3691, Vol. 45, no 12, article id 611Article in journal (Refereed) Published
Abstract [en]

Physical human–robotic interaction is a crucial area of concern for robotic exoskeletons. Lower weight requirement for the worn exoskeletons limits the number and size of joint actuators, resulting in a low active degree of freedom for the exoskeletons with joint actuators having limited power and bandwidth. This limitation invariably results in reduced physical human–robotic interaction performance for the exoskeleton. Recently several techniques have been proposed for the low active degree of freedom exoskeletons with improved physical human–robotic interaction performance using better load torque compensators and improved active compliance. However, effective practical implementation of these techniques requires special hardware and software design considerations. A detailed design of a new lower body exoskeleton is proposed in this paper that can apply these recently developed techniques to practically improve the physical human–robotic interaction performance of the worn exoskeletons. The design presented includes the exoskeleton's structural design, new joint assemblies and the design of novel 3-D passive, compliant supports. A methodology of selecting and verifying the joint actuators and estimating the desired assistive forces at the contact supports based on human user joint torque requirements and the degree of assistance is also thoroughly presented. A new CAN-based master–slave control architecture that supports the implementation of recent techniques for improved physical human–robotic interaction is also fully presented. A new control strategy capable of imparting simultaneous impedance-based force tracking control of the exoskeleton in task space using DOB-based-DLTC at joint space is also thoroughly presented. Simulation verification of the proposed strategy based on the actual gait data of elderly is presented lastly.

Place, publisher, year, edition, pages
Springer Nature , 2023. Vol. 45, no 12, article id 611
Keywords [en]
Design, Exoskeleton, Lower body, Master–slave control, Physical human–robotic interaction
National Category
Human Computer Interaction
Identifiers
URN: urn:nbn:se:kth:diva-339714DOI: 10.1007/s40430-023-04480-8ISI: 001093313100001Scopus ID: 2-s2.0-85175719993OAI: oai:DiVA.org:kth-339714DiVA, id: diva2:1813235
Note

QC 20231120

Not duplicate with DiVA 1600424

Available from: 2023-11-20 Created: 2023-11-20 Last updated: 2024-05-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Masud, NaumanSmith, Christian

Search in DiVA

By author/editor
Masud, NaumanSmith, Christian
By organisation
Robotics, Perception and Learning, RPL
In the same journal
Journal of the Brazilian Society of Mechanical Sciences and Engineering
Human Computer Interaction

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 117 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf