kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Simultaneous measurement of methane, propane and isobutane using a compact mid-infrared photoacoustic spectrophone
Zhejiang Univ, Coll Opt Sci & Engn, Ningbo Innovat Ctr, Ctr Opt & Electromagnet Res, Hangzhou 310058, Peoples R China.;Zhejiang Univ, Taizhou Hosp, Taizhou, Peoples R China..
Zhejiang Univ, Coll Opt Sci & Engn, Ningbo Innovat Ctr, Ctr Opt & Electromagnet Res, Hangzhou 310058, Peoples R China.;Zhejiang Univ, Natl Engn Res Ctr Opt Instruments, Hangzhou 310058, Peoples R China..
Zhejiang Univ, Taizhou Hosp, Taizhou, Peoples R China..
Taizhou Univ, Taizhou 318000, Peoples R China..
Show others and affiliations
2024 (English)In: Photoacoustics, ISSN 2213-5979, Vol. 39, article id 100635Article in journal (Refereed) Published
Abstract [en]

Hydrocarbon gas sensing is a challenging task using laser absorption spectroscopy due to the complex and broad structure of absorption lines. This application requires quick, accurate and highly sensitive detection of hydrocarbon gases concentrations. In this paper, a compact photoacoustic spectrophone was developed to simultaneously measure methane, propane and isobutane. This spectrophone uses wavelength modulation spectroscopy (WMS) with a single acoustic resonator and a single DFB laser emitting at 3368 nm, which greatly reduces the system complexity without using time-division multiplexing technology for multi-gas sensing. Due to the complex and broadband absorption of hydrocarbon gases, a novel signal processing method based on multilinear regression with Ridge regression (MLR-RG) is proposed to reduce the measurement error caused by the nonlinearity of spectra signal. For single gas measurement, the detection limits of methane, propane, and isobutane are determined to be 828 ppb, 419 ppb, and 619 ppb (SNR = 1, integration time = 20 s), respectively. For simultaneous multi-gas sensing in a gaseous mixture, the detection limits of propane and isobutane are determined to be 7 ppb, 68 ppb with an integration time of 860 s, 460 s, respectively. The measurement accuracy of propane and isobutane using MLR-RG is higher than that of ordinary least squares regression and partial least squares regression by 75% and 60%, respectively. The proposed algorithm based on MLR-RG provides a promising approach to process the broad overlapping absorption spectra for accurately retrieving hydrocarbon gases concentrations.

Place, publisher, year, edition, pages
Elsevier BV , 2024. Vol. 39, article id 100635
Keywords [en]
Photoacoustic spectroscopy, Multi-gas sensing, Wavelength-modulation, Second harmonic signal, Propane, Methane
National Category
Atom and Molecular Physics and Optics
Identifiers
URN: urn:nbn:se:kth:diva-352749DOI: 10.1016/j.pacs.2024.100635ISI: 001295435500001Scopus ID: 2-s2.0-85201004968OAI: oai:DiVA.org:kth-352749DiVA, id: diva2:1895762
Note

QC 20240906

Available from: 2024-09-06 Created: 2024-09-06 Last updated: 2024-09-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

He, Sailing

Search in DiVA

By author/editor
He, Sailing
By organisation
Electromagnetic Engineering and Fusion Science
Atom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 33 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf