kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Compton Polarimetry
Istituto di Astrofisica e Planetologia Spaziali (IAPS), Roma, Italy; INFN-Roma Tor Vergata, Roma, Italy.
Istituto di Astrofisica e Planetologia Spaziali (IAPS), Roma, Italy; INFN-Roma Tor Vergata, Roma, Italy.
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging. The Oskar Klein Centre for Cosmoparticle Physics, AlbaNova University Centre, Stockholm, Sweden.ORCID iD: 0000-0001-7011-7229
2024 (English)In: Handbook of X-ray and Gamma-ray Astrophysics, Springer Nature , 2024, p. 877-917Chapter in book (Other academic)
Abstract [en]

Photons preferentially Compton scatter perpendicular to the plane of polarization. This property can be exploited to design instruments to measure the linear polarization of hard X-rays (~10-100 keV). Photons may undergo two interactions in the sensitive volume of the instrument, i.e., a scattering followed by an absorption. Depending on the materials used to detect these two interactions, the Compton polarimeter can be classified as single-phase (same material for scattering and absorption detectors) or dual-phase (different materials). Different designs have been studied and adopted, and current instruments are predominantly with sensors based on scintillation or solid-state detectors. X-ray polarimetry requires much higher statistics than, e.g., spectrometry or timing; thus systematic effects must be accurately measured and accounted for. In this chapter we introduce the basic formalism of the Compton effect; we describe the design schemes developed so far for scattering polarimeters, including both the single-phase and dual-phase approaches; we overview the calibration methods to reduce the systematic effects; and we describe sources of background which affect the measurements.

Place, publisher, year, edition, pages
Springer Nature , 2024. p. 877-917
Keywords [en]
Balloon-borne instrumentation, Compact object, Compton scattering, Gamma ray burst, Polarization, Satellite-borne instrumentation, Scintillator, Solid-state detector, X-ray astrophysics, X-ray detector
National Category
Astronomy, Astrophysics and Cosmology
Identifiers
URN: urn:nbn:se:kth:diva-355918DOI: 10.1007/978-981-19-6960-7_27Scopus ID: 2-s2.0-85207533968OAI: oai:DiVA.org:kth-355918DiVA, id: diva2:1911084
Note

QC 20241107

Part of ISBN 9789811969607, 9789811969591]

Available from: 2024-11-06 Created: 2024-11-06 Last updated: 2024-11-07Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Pearce, Mark

Search in DiVA

By author/editor
Pearce, Mark
By organisation
Particle Physics, Astrophysics and Medical Imaging
Astronomy, Astrophysics and Cosmology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 107 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf