kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Thermal performance study of buildings and their corresponding scale models with identical constructions and geometrical similarity
Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China..
KTH, School of Architecture and the Built Environment (ABE), Urban Planning and Environment, Urban and Regional Studies.
2024 (English)In: JOURNAL OF ENGINEERING RESEARCH, ISSN 2307-1877, Vol. 12, no 4, p. 599-609Article in journal (Refereed) Published
Abstract [en]

Small-scale physical model testing can be applied to calibrate a computational building energy model based on the acquired reliable thermal performance data. The calibration approach using a small-scale physical model is a rigorous and cost effective means in order to do an accurate full-scale building energy simulation. It is meaningful to reveal the correlation of the thermal performance between a full-scale building and its scale model, so that the data from a small-scale model testing can be scalable to predict the performance of a full-scale building. The purpose of the research is to investigate the correlations reflecting the comparative thermal performance of a full-scale building against its scale model with identical constructions and geometrical similarity. More than ninety thousand scenarios about the typical target building zones and their corresponding scale models were generated via the parametric energy modeling and simulation approach. Then, the typical thermal performance indicator of each building zone, i.e. the zone mean air temperature (ZMAT), was obtained. The result shows that the zone mean air temperature difference between the target building and its scale model is a time dependent variable with the diurnal cycle. Compared with a fixed scale model, the bigger building causes the larger variation of zone mean air temperature difference. Furthermore, it also indicates that the zone mean air temperature difference can be approximated by a logarithmic regression function as ALn(SF/d) + B, where A and B are empirical coefficients associated with climate, building form, material and construction, as well as window-towall ratio. In engineering practice, the outcomes of the research are applicable for thermal performance estimation and energy model calibration of full-scale buildings, especially for a planned building with the available material and construction samples, but without the determined or reliable thermal performance data for the building.

Place, publisher, year, edition, pages
Elsevier BV , 2024. Vol. 12, no 4, p. 599-609
Keywords [en]
Geometrical similarity, Scale model, Scaling effect, Thermal performance, Zone mean air temperature
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-359524DOI: 10.1016/j.jer.2023.10.022ISI: 001394275800001Scopus ID: 2-s2.0-85186209896OAI: oai:DiVA.org:kth-359524DiVA, id: diva2:1934902
Note

QC 20250205

Available from: 2025-02-05 Created: 2025-02-05 Last updated: 2025-02-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Xu, Miao

Search in DiVA

By author/editor
Xu, Miao
By organisation
Urban and Regional Studies
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 32 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf