Electrically induced hemodynamic enhancement via sock-integrated electrodes is more comfortable and efficient at 1 hz as compared to 36 hz
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Smart Textiles and Polymeric E-textiles, Swedish School of Textiles, University of Borås, Borås, Sweden.
Show others and affiliations
2025 (English)In: Scientific Reports, E-ISSN 2045-2322, Vol. 15, no 1, article id 12944Article in journal (Refereed) Published
Abstract [en]

This study evaluated the hemodynamic effects, discomfort, and energy efficiency of low-intensity neuromuscular electrical stimulation (LI-NMES) of the calf delivered via sock-integrated transverse textile electrodes (TTE) at different frequencies and plateau times. Fifteen healthy participants underwent NMES stimulation through 3 × 3 cm TTE with ten combinations of frequency (1–36 Hz) and plateau times (0.5–7 s). NMES was increased until plantar flexion occurred, at which point ultrasound-measurements were made of popliteal peak venous velocity (PVV), time-averaged mean velocity (TAMV), average duration of blood flow pulse (ADBP) and ejection volume (EV). Discomfort (NRS, 0–10), current amplitude, and energy consumption were recorded. Median values were analyzed with significance set at p < 0.05. Both 1 Hz and 36 Hz C-LI-NMES significantly improved PVV and TAMV (p ≤ 0.008). EV increased significantly for plateau times of 1.5, 5.0, and 7.0 s (p < 0.05). Compared to 36 Hz, 1 Hz showed significantly lower discomfort (NRS: 0.4 vs. 1.6) and energy consumption (0.4 vs. 31.3 mJ, both p ≤ 0.01) but required higher current amplitude (33.2 vs. 23.3 mA, p < 0.01) to reach plantar flexion. The study concludes that both 1 Hz and 36 Hz frequency improve venous hemodynamics, but 1 Hz stimulation minimizes discomfort and energy use while maintaining effectiveness. Trial registration: Retrospectively registered with Clinical Trials, trial ID: NCT06082297.

Place, publisher, year, edition, pages
Springer Nature , 2025. Vol. 15, no 1, article id 12944
Keywords [en]
Electric stimulation therapy, Hemodynamics, Motor point, NMES, Pain, Textile electrodes
National Category
Physiology and Anatomy
Identifiers
URN: urn:nbn:se:kth:diva-363109DOI: 10.1038/s41598-025-97431-3ISI: 001468488100041PubMedID: 40234723Scopus ID: 2-s2.0-105003308867OAI: oai:DiVA.org:kth-363109DiVA, id: diva2:1956358
Note

QC 20250507

Available from: 2025-05-06 Created: 2025-05-06 Last updated: 2025-05-07Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Rodriguez, Saul

Search in DiVA

By author/editor
Rodriguez, Saul
By organisation
Electronics and Embedded systems
In the same journal
Scientific Reports
Physiology and Anatomy

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 111 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf