kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Monitoring Acetone with Photoacoustic Spectroscopy Using a Metal–Organic Framework
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China; Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Taizhou Hospital, Zhejiang University, Taizhou, 318000, P. R. China.
Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310058, P. R. China.
Show others and affiliations
2024 (English)In: Advanced Optical Materials, ISSN 2162-7568, E-ISSN 2195-1071, Vol. 12, no 10, article id 2302280Article in journal (Refereed) Published
Abstract [en]

Herein, this study describes a sample preconcentration apparatus based on a metal–organic framework (MOF) of NH2-UIO-66@PDMS adsorbent, which is first coupled to photoacoustic spectroscopy (PAS) technology for detection of acetone. The MOF selectively traps acetone out of complex samples and releases it into the photoacoustic (PA) cell, where PA signal intensity is recorded by PAS sensing system based on a cheap amplitude modulated UV LED as light source. The signal intensity is enhanced by 11 times after preconcentration of NH2-UIO-66@PDMS (100 mg). The preconcentration apparatus not only enhances sensitivity of sensor, but also promotes the anti-interference ability for common interferents (carbon dioxide, oxygen and water vapor, ethanol, propanol, etc.) of the sensor. As expected, the established PA sensor possesses a detection limit of 0.23 ppm for measuring acetone, which can feasibly be applied for the analysis of acetone in patients breath samples. This work provides a good example of the preconcentration effect of MOF for promoting PA sensor analytical performance, and the prospect of medical diagnosis.

Place, publisher, year, edition, pages
Wiley , 2024. Vol. 12, no 10, article id 2302280
Keywords [en]
acetone, NH2-UIO-66@PDMS, photoacoustic sensor, preconcentration, UV LED
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-367017DOI: 10.1002/adom.202302280ISI: 001153384400001Scopus ID: 2-s2.0-85183620754OAI: oai:DiVA.org:kth-367017DiVA, id: diva2:1983951
Note

QC 20250714

Available from: 2025-07-14 Created: 2025-07-14 Last updated: 2025-07-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

He, Sailing

Search in DiVA

By author/editor
He, Sailing
By organisation
Electromagnetic Engineering and Fusion Science
In the same journal
Advanced Optical Materials
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 31 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf