Novel Customizable Fracture Fixation Technique vs. Conventional Metal Locking Plate: An Exploratory Comparative Study of Fixation Stability in an Experimental In Vivo Ovine Bilateral Phalangeal Fracture Model
Department of Orthopaedic Surgery, Rigshospitalet, University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark; Department of Orthopaedic Surgery, Hvidovre University Hospital, Kettegaard Alle 36, Copenhagen, 2650, Denmark.
Department of Orthopaedic Surgery, Hvidovre University Hospital, Kettegaard Alle 36, Copenhagen, 2650, Denmark; Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Agrovej 8, Copenhagen, 2630, Denmark.
Department of Orthopaedic Surgery, Herlev-Gentofte University Hospital, Gentofte Hospitalsvej 1, Copenhagen, 2900, Denmark.
Department of Orthopaedic Surgery, Rigshospitalet, University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark.
Show others and affiliations
2025 (English)In: Materials, E-ISSN 1996-1944, Vol. 18, no 14, article id 3359Article in journal (Refereed) Published
Abstract [en]

A novel composite patch osteosynthesis technique (CPT) has demonstrated promising ex vivo biomechanical performance in small tubular bones. To bridge the gap toward clinical evaluations, this study compared the stability of the CPT to a stainless-steel locking plate (LP) in an experimental in vivo ovine bilateral proximal phalanx fracture model. Eight sheep underwent a midline osteotomy with a 4.5 mm circular unicortical defect in the lateral proximal phalanx of both front limbs, treated with the CPT (n = 8) or the LP (n = 8). A half-limb walking cast, or a custom off-loading hoof shoe, was used for postoperative protection. Implant stability was assessed by post-surgery X-ray evaluations and post-euthanasia (16 weeks) dual-energy X-ray absorptiometry (DXA). At week one, all CPT implants demonstrated mechanical failure, while all LPs remained overall intact. Mean BMD was 0.45 g/cm2 for CPT and 0.60 g/cm2 for LP in the fracture area (p = 0.078), and 0.37 g/cm2 vs. 0.41 g/cm2 in the distal epiphysis (p = 0.016), respectively. In conclusion, the CPT demonstrated indications of inferior stability compared to the LP in this fracture model, which may limit its clinical applicability in weight-bearing or high-load scenarios and in non-compliant patients.

Place, publisher, year, edition, pages
MDPI AG , 2025. Vol. 18, no 14, article id 3359
Keywords [en]
biomechanical stability, fracture fixation, in vivo ovine fracture model
National Category
Orthopaedics Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-368591DOI: 10.3390/ma18143359ISI: 001535644100001PubMedID: 40731567Scopus ID: 2-s2.0-105011621427OAI: oai:DiVA.org:kth-368591DiVA, id: diva2:1989973
Note

QC 20250819

Available from: 2025-08-19 Created: 2025-08-19 Last updated: 2025-11-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Hutchinson, Daniel JohnMalkoch, Michael

Search in DiVA

By author/editor
Hutchinson, Daniel JohnMalkoch, Michael
By organisation
Coating Technology
In the same journal
Materials
OrthopaedicsRadiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 79 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf