kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
GaN-Based Three-Phase Voltage and Current Sources for Power Relay Testing
Department of Electrical Engineering, University of Guanajuato, Salamanca, Guanajuato, Mexico.ORCID iD: 0000-0003-4890-1783
Department of Electrical Engineering, University of Guanajuato, Salamanca, Guanajuato, Mexico.ORCID iD: 0009-0003-0926-6147
Department of Electrical Engineering, University of Guanajuato, Salamanca, Guanajuato, Mexico.
Department of Electrical Engineering, National Autonomous University of Mexico (UNAM, in Spanish), Mexico City, Mexico.ORCID iD: 0000-0002-2121-6420
Show others and affiliations
2025 (English)In: IET Power Electronics, ISSN 1755-4535, E-ISSN 1755-4543, Vol. 18, no 1, article id e70092Article in journal (Refereed) Published
Abstract [en]

This paper implements low-cost GaN-based three-phase voltage and current sources to validate power protecting relays. This proposal develops a voltage generator that uses three single-phase full-bridge converters equipped with an LC filter and an isolating transformer. It also includes a current generator using three single-phase half-bridge converters furnished with an LCL filter. Both voltage and current testing sources are assembled employing GaN transistor technology, which enables operation at high switching frequencies and passive filters with low-value components. Experimental tests are conducted to confirm and validate the operation and dynamic performance of voltage and current testing sources. Finally, the performance of the voltage and current signal generator is assessed by testing a commercial protection system (SEL-451) through directional current function. This is achieved by emulating a fault condition, where three voltage and current signals are generated to trigger the trip signal after surpassing the relay threshold.

Place, publisher, year, edition, pages
Institution of Engineering and Technology (IET) , 2025. Vol. 18, no 1, article id e70092
Keywords [en]
DC-AC power convertors, overcurrent protection, power electronics
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-369865DOI: 10.1049/pel2.70092ISI: 001644569100014Scopus ID: 2-s2.0-105013969506OAI: oai:DiVA.org:kth-369865DiVA, id: diva2:1998208
Note

QC 20250916

Available from: 2025-09-16 Created: 2025-09-16 Last updated: 2026-05-29Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Chamorro Vera, Harold Rene

Search in DiVA

By author/editor
Merchan-Villalba, Luis RamónCano-Gallardo, Juan M.Arrieta Paternina, Mario R.Lozano-Garcia, Jose M.Pizano-Martinez, AlejandroTapia-Tinoco, GuillermoChamorro Vera, Harold Rene
By organisation
Electric Power and Energy Systems
In the same journal
IET Power Electronics
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 111 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf