A lanthanum bromide detector of runaway electrons for TCV
École Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.ORCID iD: 0000-0002-5838-5076
Institute of Plasma Physics of the CAS, Prague, Czech Republic; FNSPE, Czech Technical University in Prage, Prague, Czech Republic.ORCID iD: 0000-0001-6051-4001
École Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.ORCID iD: 0000-0003-0220-2653
École Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.ORCID iD: 0000-0001-7783-129X
Show others and affiliations
2025 (English)In: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 96, no 9, article id 093501Article in journal (Refereed) Published
Abstract [en]

The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼ 8 M e V on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.

Place, publisher, year, edition, pages
AIP Publishing , 2025. Vol. 96, no 9, article id 093501
National Category
Fusion, Plasma and Space Physics Subatomic Physics
Identifiers
URN: urn:nbn:se:kth:diva-370146DOI: 10.1063/5.0277312ISI: 001566040600001PubMedID: 40905794Scopus ID: 2-s2.0-105015298327OAI: oai:DiVA.org:kth-370146DiVA, id: diva2:2000394
Note

QC 20250924

Available from: 2025-09-24 Created: 2025-09-24 Last updated: 2025-09-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Hoppe, Mathias

Search in DiVA

By author/editor
Simons, L.Cerovsky, J.Decker, J.Duval, B. P.Ficker, O.Hoppe, MathiasSheikh, U.
By organisation
Electromagnetic Engineering and Fusion Science
In the same journal
Review of Scientific Instruments
Fusion, Plasma and Space PhysicsSubatomic Physics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 104 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf