kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
TCT-based monitoring of LGAD radiation hardness for ATLAS-HGTD production
Department of Experimental Particle Physics, Jožef Stefan Institute and Department of Physics, University of Ljubljana, Ljubljana, Slovenia.
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging.ORCID iD: 0000-0001-9415-7903
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging.ORCID iD: 0000-0002-8015-7512
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging.ORCID iD: 0000-0002-8913-0981
Show others and affiliations
Number of Authors: 2312026 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 1084, article id 171195Article in journal (Refereed) Published
Abstract [en]

Production of the High Granularity Timing Detector for the ATLAS experiment at High Luminosity LHC requires over 21000 silicon sensors based on Low Gain Avalanche Diode (LGAD) technology. Their radiation hardness is monitored as a part of the production quality control. Dedicated test structures from each wafer are irradiated with neutrons and a fast and comprehensive characterization is required. We introduce a new test method based on Transient Current Technique (TCT) performed in the interface region of two LGAD devices. The measurement enables extraction of numerous sensor performance parameters, such as LGAD gain layer depletion voltage, LGAD gain dependence on bias voltage, sensor leakage current and effective interpad distance. Complementary capacitance-voltage measurements and charge collection measurements with 90Sr on the same samples have been performed to calibrate the TCT results in terms of charge collection and define acceptance criteria for wafer radiation hardness in the ATLAS-HGTD project.

Place, publisher, year, edition, pages
Elsevier BV , 2026. Vol. 1084, article id 171195
Keywords [en]
ATLAS, Charge multiplication, HGTD, Irradiations, Low Gain Avalanche Diodes, Time resolution, Transient Current Technique
National Category
Subatomic Physics Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-374021DOI: 10.1016/j.nima.2025.171195Scopus ID: 2-s2.0-105023299732OAI: oai:DiVA.org:kth-374021DiVA, id: diva2:2021037
Note

QC 20251212

Available from: 2025-12-12 Created: 2025-12-12 Last updated: 2025-12-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Leopold, AlexanderOhm, ChristianStrandberg, JonasVande Voorde, Magdalena

Search in DiVA

By author/editor
Leopold, AlexanderOhm, ChristianStrandberg, JonasVande Voorde, Magdalena
By organisation
Particle Physics, Astrophysics and Medical Imaging
In the same journal
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Subatomic PhysicsOther Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 65 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf